Nominal Capacities
2.5 - 6.3 Tons

Efficiency
13 SEER (Up To 15 SEER)

Warranty
Compressor - 5-Years Limited*
Parts - 1-Year Limited*
LX Series 13 SEER R-410A Split System Air Conditioner (TCJD 3 Phase)

     The LX Series TCJD models are the outdoor part of a versatile air conditioning system.  They are designed to be custom matched with one of our complete line of evaporator sections, each designed to serve a specific function.  Matching air handlers are available for upflow, downflow, and horizontal left or right applications to provide a complete system.  Alternately, add-on coils are available for use with modular air handlers or upflow, downflow, and horizontal furnaces.  Electric heaters and field installed accessories are also available as needed.  Most models offer combinations that achieve Energy Star® efficiency levels.

Special Benefits
  • Small Footprint - Extremely lightweight with a compact footprint, it is a perfect fit for any application.
  • Quality Condenser Coils - The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins for reduced size and increased efficiency.
  • Coil Protection - Coils are protected from damage by a slotted, stamped steel coil guard and secondary polymer mesh.
  • Protected Compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high pressure switch.  A factory installed liquid line filter-drier further protects the compressor against moisture and debris.
  • Environmentally Friendly Refrigerant - The next generation refrigerant R-410A delivers environmentally friendly performance with zero ozone depletion.
  • Durable Finish - The cabinet is made of pre-painted steel.  The pre-treated, galvanized steel provides a better paint-to-steel bond, which resists corrosion and rust creep.  Special primer formulas and matte champagne finish insure less fading when exposed to sunlight.
  • Lower Installed Cost - Installation time and costs are reduced by easy power and control wiring connections.  The unit is factory charged for a 15-foot lineset.  The small base dimension means less space is required on the ground or roof.
  • Top Discharge - Warm air from the top mounted fan is blown up, away from the structure and any landscaping.  This allows compact location on multi-unit applications.
  • Low Operating Sound Level - The upward air flow carries the normal operating noise away from the living area.  The rigid top panel effectively isolates any motor sound.  Isolator mounted compressor and the condenser coil muffle the normal fan motor and compressor operating sounds.
  • Low Maintenance - Long life, permanently lubricated motor-bearings need no annual servicing.
  • Easy Service Access - Fully exposed refrigerant connections and a single panel covering the electrical controls make for easy servicing of the unit.
  • Secured Service Valves - Secured, re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
  • Agency Listed - Safety certified by CSA to UL 1995 / CSA 22.2.  Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification program.

*Register online within 90 days of installation.  This warranty does not apply to R-22 models or internet sales.  See the Limited Warranty certificate in the User's Information Manual for details.

Verify the actual ratings for each specific matchup in the online AHRI directory at www.ahridirectory.org at the time of sale.  It is also recommended to print the rating certificate, if needed, at the time of sale.

Publications and Manuals
DescriptionPart NumberFile Size
Consumer Brochures
Consumer Brochure - LX Series Air Conditioners with MicroChannel Technology (13 SEER)PUBL-6184-C-0710844.0 KB PDF
Tech Guides
Technical Guide - TCJD30 thru 60 3Ø R-410A Split System Air Conditioner (13 SEER)545137-BTG-C-0510467.0 KB PDF
Tabular Data
Tabular Data Sheet - TCJD30* thru 60, 1Ø R-410A Outdoor Split System Air Conditioner (13 SEER)833097-UTD-A-0312214.0 KB PDF
Tabular Data Sheet - TCJD30* thru 60, 3Ø Split System Air Conditioner (13 SEER)529068-UTD-C-0510184.0 KB PDF
Tabular Data Sheet - TCJD76*, 1Ø R-410A Outdoor Split System Air Conditioner (13 SEER)813192-UTD-A-0312180.0 KB PDF
Submittal Drawings
Submittal Data Sheet - TCJD30* thru 60 3Ø R-410A Split System Air Conditioner (13 SEER)545138-USD-A-1209212.0 KB PDF
Repair Parts
Repair Parts - TCJD Series 13 Seer Air Conditioners, R-410A, 3 Ph, 3rd Gen (A)035-22748-001-F-0512445.0 KB PDF
Repair Parts - TCJD Series 3 Phase (3rd Gen) MicroChannel R-410A Air Conditioner E-Coated Coils (13 SEER) "Style A"035-23910-001-B-0512442.0 KB PDF
Repair Parts - TCJD Series 3-Phase R-410A Microchannel Air Conditioners, 4th Generation "Style A" (13 SEER)035-23096-001-C-0512433.0 KB PDF
User Manuals
User's Information Manual - 1Ø and 3Ø Split System Air Conditioner or Heat Pump Units813196-UUM-C-0412119.0 KB PDF
Get a good feeling for how good your business can be—contact Luxaire today!

© 2012 Johnson Controls, Inc. All rights reserved.
Site Map | Terms and Conditions | Privacy Policy
Are you a homeowner? Visit Luxaire.com
Make-A-Wish
NATE Certified